问答 #32526 - 11.1 Spartan-3A PLACE Known Issues - Crash during Phase 4.2 of MAP or PAR

全部最近问答记录

搜索问答数据库


 

11.1 Spartan-3A PLACE Known Issues - Crash during Phase 4.2 of MAP or PAR

问答编号# 32526
型号 SW-Place
最后更新日期 2009-04-23 00:00:00.0
记录状态 Active
关键词 4.2, place, crash

疑问描述

Keywords: 4.2, place, crash

My Spartan-3E/A design is crashing during the Phase 4.2. What is this phase and is this a known problem?

解决方案

Phase 4.2 is the clock placement phase where the location of clock components is determined or, in the case of locked components, validated. There is a known problem in ISE 11.1 where when a certain error condition is detected, the error handling code causes a crash. This error condition should trigger the following error message:

ERROR:Place:1264 - A conflict between the loads of two BUFGs has been found.
There is a restriction that no pair of BUFGs can drive loads in the same
quadrant of the device.

This error occurs when there is a conflict between an All-Quadrant BUFG and its paired Side BUFG which can not drive loads in the same clock region due to shared routing resources. For more information on this restriction see (Xilinx Answer 19947).

This problem will be fixed in ISE 11.2. Meanwhile, examine the BUFG locations chosen for the conflicts mentioned above.
 
 