问答 #33016 - Spartan-6 FPGA Clocking - DCM de-skew calculations incorrect

全部最近问答记录

搜索问答数据库


 

Spartan-6 FPGA Clocking - DCM de-skew calculations incorrect

问答编号# 33016
型号 FPGA-Spartan-Clock Manager
最后更新日期 2009-10-30 00:00:00.0
记录状态 Active
关键词 deskew, adjust, default, dcm, feedback,

疑问描述

Keywords: deskew, adjust, default, dcm, feedback,

The Spartan-6 FPGA DCM default de-skew settings are incorrect.

解决方案

In the ISE 11.2 software, the default de-skew setting for the DCM is incorrectly set. The tools default to a setting of "9" for the de-skew value, when the actual value should be "0". This will result in added skew to your output clock when compared to your input reference clock.

To correct the issue, you can manually set the DCM de-skew value to "0". To do this, you must enter the FPGA Editor tool, locate the DCM, change to "Edit Mode", and check the "0" box.

This issue will be fixed in a future version of ISE software.
 
 