UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 10024

Timing Analyzer 3.1i - Timing Analyzer does not report label (-Th) for a hold violation

描述

General Description:

Timing Analyzer does not report label (-Th) for a hold violation, making it inconsistent with TRCE:

TRCE: CLB_R39C2.S1.CLK....................Tcki........(-Th).....-0.766

Timing Analyzer: CLB_R39C2.S1.CLK.....Tcki....................-0.766F

解决方案

Use TRCE from the command line to obtain the correct results.

This problem was reproduced using D.25. In the XML file that Timing Analyzer uses to generate the report, this delay is correctly tagged with the twHoldTime="TRUE" attribute.

NOTE: To get the path with the Tcki delay in the report, use the skew check option.

This problem was approved by the RCB to be fixed in D Service Pack 8.

AR# 10024
日期 01/18/2010
状态 Archive
Type 综合文章
的页面