UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 13674

9.1i PrimeTime - Negative-edge flip-flops produce different slack values than those reported in TRCE/Timing Analyzer

描述

I have created OFFSET IN constraints on several negative-edge flip-flops. When I perform timing analysis through PrimeTime, the slack numbers are different than those reported in the TRCE/Timing Analyzer analysis. Which slack equation is correct?

解决方案

In Timing Analyzer, it might appear that the software is adding the PERIOD into the positive-edge register's OFFSET calculation if the OFFSET constraint and PERIOD constraint have the same requirement. To avoid this ambiguity, ensure that your OFFSET constraint value does not match your PERIOD constraint value.

Another possible conflict in the slack numbers can occur because occasionally PrimeTime does not take the half-PERIOD lost on negative-edge flip-flops into account. This results in the SLACK numbers differing by half the PERIOD.

AR# 13674
日期 01/18/2010
状态 Archive
Type 综合文章
的页面