描述

For Xilinx 5 Volt FPGA families XC2000, XC3000, XC4000(E) and XC5200, the input and output threshold level of CCLK is compatible with both 5 Volt TTL and 5 Volt CMOS threshold standards.

解决方案

Xilinx FPGAs use CMOS transistors, but mimic a BJT-like structure in that outputs drop a threshold on the VOH. Therefore, when CCLK is used as an output, it swings from 0 to 4.0 volts. As an input the CCLK triggers at a threshold of 1.5 Volts. This is compatible with both TTL and CMOS threshold standards:

Thres. TTL CMOS

----------------------------------

VILmax 0.8 1.0

VIHmin 2.0 70% (Vcc)

VOLmax 0.4 0.4

VOHmin 2.4 Vcc - 0.5V

Therefore, CCLK may be used to source or load either TTL or CMOS type external circuitry.