AR# 154

XC4000H: Computing output transition time for 4000H

解决方案




In XCELL #9, the output transition time is specified to be 6ns at 150pf and
3ns at 50pf. This can be reasonably extrapolated linearly as a 3ns increase
in transition time for each addition of 100pf of load.