UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 15840

3.1 EDK - I updated my MDK system using the "revup" utility, and a POSITION attribute now appears. What is this attribute?

描述

Keywords: POSITION, EDK, MHS, revup

Urgency: Standard

General Description:
When I update a MicroBlaze Design Kit .mhs file using the "revup utility", a POSITION attribute is added to the BUS_INTERFACE setting. What does this attribute do? Is it necessary?

解决方案

The POSITION attribute is intended for multiple-master buses, and is used to set priority among those masters. (More information is available in the EST Guide, under the "Local Bus Interface Command" heading.) For a system in which multiple masters are not used on a single bus, this attribute may be safely ignored or removed.

This problem is fixed in the latest 3.1 EDK Service Pack, available at:
http://www.xilinx.com/ise/embedded/edk.htm.
The first service pack containing the fix is EDK 3.1 Service Pack 2.
AR# 15840
日期 04/28/2006
状态 Archive
Type 综合文章
的页面