5.1i Timing - Cross-clock paths are not listed by destination clock in the unconstrained path report

描述

General Description:

The Unconstrained Path Report contains cross-clock domain paths that are not shown under the corresponding destination clock. Instead, they are displayed under the General Unconstrained Path section. When will this be fixed?

解决方案

This problem is fixed in the latest 5.1i Service Pack, available at:

http://support.xilinx.com/support/techsup/sw_updates
The first service pack containing the fix is 5.1i Service Pack 3.