6.1i ISE - Closing Timing Analyzer produces an error message in the Project Navigator Console window: "can't read "_processlabel": no such variable"

描述

Keywords: TCL, ISE, TA, Timing Analyzer, TimingAn, processlabel, process label

Urgency: Standard

General Description:
I open Timing Analyzer through a Project Navigator process such as "Post-Map Static Timing Report". Once Timing Analyzer is closed, the following message appears in the transcript window:

"can't read "_processlabel": no such variable
while executing
"filesToDelete "$DID_File" "# Implmentation : $_processlabel""
(file "<Xilinx directory>/data/projnav/scripts/_runTimingan.tcl" line 71)

OS = XP Prof."

解决方案

This message may safely be ignored. The error does not stop any flow processes and addresses only the cleanup after the Timing Analyzer window is closed. You can still edit/save, etc., any files in Timing Analyzer and also later run any process downstream without difficulty.

This problem has been fixed in the latest 6.1i Service Pack, available at:
http://support.xilinx.com/support/techsup/sw_updates
The first service pack containing the fix is 6.1i Service Pack 1.