UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 18179

6.1i SimPrim, Simulation - Post fit simulation shows data reaction on rising edge instead of falling edge

描述

Keywords: ISE6.1, ModelSim, library, timing, simulation, rising, falling, edge, XC9500XL

Urgency: Standard

General Description:
Post fit simulation of a XC9500XL design shows data reaction on rising edge instead of falling edge. Behavioral simulation shows the right result as well as post fit simulation with previous libraries (ISE5.2).

解决方案

This problem is caused by a double inversion on the global clocks. The double inversion occurs when inverted global clocks are created by the user or the software.

To work around this problem, uncheck "Use Global Clocks" from Project Navigator.

This will cause a pterm clock to be used, and the double inversion will not occur.

This problem has been fixed in 6.1i Service Pack 3.
AR# 18179
日期 11/18/2008
状态 Archive
Type 综合文章
的页面