In some circumstances, the HW-130 Programmer may issue the following message:
WARNING! PROGRAMMING ERROR AT ADDRESS 0018
on XC73144 devices. (The actual address flagged in the error message may vary.)
The problem is related to the use of the Ground Control pins in the XC73144 devices. The Ground Control pins are utilized when you specify the -u option to FITNET/FITEQN to "Drive Unused I/O Pads On Chip".
A conflict arises because when the pins are used for logic, they cannot be driven to ground.)
解决方案
1
One workaround is to recompile the design WITHOUT the -u option and tie pullups or pulldowns to any unused I/O on the device.
2
Use the 6.0.x software on the PC to generate the .PRG files, instead of the 5.2.1 software on the PC/Workstation.