AR# 19796

6.2.2 EDK - NCSIM issues the following error: "SMART MODEL INTERFACE: Model needs a greater Time Unit resolution"

描述

Keywords: NCSIM, Smart Model, SmartModel, FMI Error

Urgency: Standard

General Description:
I am running a simulation which utilizes the PowerPC SmartModel. NCSIM issues the following error:

"SMART MODEL INTERFACE: Fatal error in SmartModel initialization!
SMART MODEL INTERFACE: Model needs a greater Time Unit resolution
SMART MODEL INTERFACE: Instance is
SMART MODEL INTERFACE:
system_tb:system_stub:system:ppc405_i:PPC405_I:PPC405_I:IPPC405_SWIFT:PPC405
_SWIFT_INST
Error! FMI error
From
system_tb:system_stub:system:ppc405_i:PPC405_I:PPC405_I:IPPC405_SWIFT:PPC405
_SWIFT_INST (SWIFT PPC405_SWIFT)...
Terminating execution of the Smartmodel Interface!
Time: 0 FS + 0
SMART MODEL INTERFACE: This Session is FATAL and must be restarted"

解决方案

Set the following environment variable:

LMC_TIMEUNIT = -12