UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 20100

CPLD CoolRunner-II - Can Vccaux be disconnected or grounded to save power?

描述

Can I disconnect or ground the Vaux pin to save power on a CoolRunner-II CPLD?

解决方案

No, the Vaux pin cannot be disconnected or grounded to save power on a CoolRunner-II CPLD.

Vaux powers the JTAG I/O buffers, and floating or grounding this pin will result in unknown values being passed from these buffers to the core of the CPLD. This action can result in unexpected behavior in the JTAG state machine that can lead to a functional failure.

AR# 20100
日期 12/15/2012
状态 Active
Type 综合文章
的页面