UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 20140

6.3i iMPACT - Configuration with the SVF or ACE file running at high TCK speed might result in configuration failure

描述

General Description:

Configuration with the SVF or ACE file running at high TCK speed might result in configuration failure. iMPACT generates long RUNTEST TCK counts assuming TCK running at 1 MHz. If running TCK frequency faster than 1 MHz, you should modify accordingly any RUNTEST TCK counts over 1000.

解决方案

iMPACT generates long RUNTEST TCK counts assuming TCK running at 1 MHz. If running TCK frequency faster than 1 MHz, you should modify accordingly any RUNTEST TCK counts over 1000. This should be taken care of, and the service pack will not account for any TCK frequency other than 1 MHz.

For Virtex-4 ES parts, it is critical to wait for a longer period of time for the current draw to subside.

This particular problem has been fixed in the latest 6.3i Service Pack available at:

http://support.xilinx.com/xlnx/xil_sw_updates_home.jsp
The first service pack containing the fix is 6.3i Service Pack 2.

AR# 20140
日期 12/15/2012
状态 Active
Type 综合文章
的页面