UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 2066

Foundation Schematic - "PPR ERROR 9028" encountered when using COMPMC8 macro in a 5200 design

Description

Keywords: PPR, Foundation, 9028

Urgency: Standard

General Description:
The following error may occur during the Place and Route of an XC5200 design:

*** PPR: ERROR 9028:
The following block of the set $I2/hset does not represent a legal block
configuration for this device. Check the logic shown below against the
requirements of RLOC constraints, BLKNM parameters, and X and P signal
parameters.

Symbol Name = $I2/$1I3
Type = CY_MUX
RLOC = R1C1.LC0
Symbol Name = $I2/$1I1965
Type = CY_MUX
RLOC = R1C1.LC0
....

Note that in the line "RLOC = R1C1.LC0", the RLOC attributes refer to column 1 instead
of column 0. This is an error in the Foundation XC5200 library.

解决方案

1

In order to use the COMPMC8 in an XC5200 design, you must make a local copy of the
macro and edit it to correct the RLOC attributes.

Please see (Xilinx Solution 1657) for instructions on copying a Xilinx library component.

Open up the macro schematic and modify all the RLOC attributes for the 'LT' logic to use
column 0 'C0'.

2

For the correct schematics, refer to Page 3-48 in the On-Line Libraries Supplement Guide.
AR# 2066
创建日期 08/31/2007
Last Updated 10/06/2008
状态 Archive
Type 综合文章