UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 21644

LogiCORE FIFO Generator v2.1 - How do you disable FWFT for an independent clock FIFO?

描述

General Description: 

How do you disable FWFT for an independent clock FIFO?

解决方案

When using the independent clock FIFO, FWFT is supported and must be enabled by selecting Registered Outputs with Read Latency 0, as indicated on page 5 of the datasheet (note 2). 

 

FWFT can be enabled only if Registered Outputs AND Read Latency is 0. If the Read Latency is not 0, FWFT should not be placed in FIFO indepedent clock mode.

AR# 21644
日期 05/19/2014