Orcad Capture - Design rule check gives "no matching pin" error for OFD16 component
描述
Keywords: Orcad, Capture, OFD16, pins, matching
Urgency: Standard
General Description: When I use an OFD16 in an Orcad Capture design, I encounter the following warning from the design rule checker:
[DRC0012] Pin has no matching port in schematic below U... and [DRC0013]: Port has no matching pin in part instance above...
解决方案
This warning message may be due to a problem with the library symbol. Descend into the OFD16 component and see if the output and input bus names have an index [15.0] instead of [15..0] as they should. (This was a problem in the original Capture libraries.) If so, change the bus index to [15..0].
Orcad has been notified of this error.