AR# 2196

5200: Readback with xchecker on 5202 devices

描述

Keywords: 5200, 5202, readback, XACTstep 5.2.1/6.0.1, xchecker

Urgency: Hot

Description

XACTstep 5.2.1/6.0.1 can not perform readback with xchecker on
5202 devices.

解决方案

Current XACTstep 5.2.1/6.0.1 does not support readback with xchecker for 5202. However, readback is supported in the rest
of 5200 family. makebits program needs to run with following options:


Makebits -l -f readcapture:enable <design>


Users should understand this is not an architectural problem
but a software limitation.
AR# 2196
日期 01/12/2003
状态 Archive
Type 综合文章