UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 2268

Concept2xil - Concept2xil causes NGDBUILD to issue "ERROR:based:48-..Duplicate port a in cell "alias_bit".

Description

Keywords: Concept, Concept2xil, NGDBuild, edif2ngd

Urgency: Standard

General Description:
NGDBUILD or Edif2NGD may issue the following error on a
Concept design that contains buses:

<output>
ERROR:based:48 - On or above line 371 in file "calc.edf":
Duplicate port a in cell "alias_bit". This likely means
that the EDIF netlist was improperly written. Please
contact the vendor of the program that produced this EDIF
file.
</output>

解决方案

One cause of this is tapping bits off a bus (with SLICE),
and "renaming" those nets to other netnames. "Renaming" nets
tapped off a bus bus means naming a bus bit using any
deviation from the "busname<bit_number>" convention.

Renaming nets is notlegal with HDL Direct methodology.
For instance, if you have an 8 bit bus "mybus<7..0>", and you
wish to tap bit 5 off, then the net that comes from the SLICE
or TAP must be either unnamed, or labelled as "mybus<5>".
Naming the net "mybus5" would be incorrect without inserting a BUFF
component (buffer) in between this net and the bus or SLICE.

To rename a net that has been sliced/tapped off a bus, you
may run the net to a BUFF, and then rename the output of the
BUFF to a new netname.

Consult Cadence's OpenBook and also Xilinx's Cadence
Interface/Tutorial Guide for more information on HDL Direct
naming methodology.