LogiCORE PCI Express - Memory Read to Xilinx core is returning all 1s

描述

Some customers have reported that if they send a Memory Read to their user application from the root complex or switch, the core returns all 1s in the completion with data.

解决方案

This issue occurs on some systems if the user does not correctly set the Attribute field in the completion with data TLP header. In particular, it seems some systems require the completion to set the value of the No Snoop bit (bit 0 of the two-bit attribute field) to be the same as the No Snoop bit in the original Memory Read TLP. 

 

The problem is not that the core is returning all 1s in the CplD as the data passed by the user is passed unchanged to the link, the issue is that the processor/root is treating the packet as malformed and not passing the data.