UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 22761

9.2i XST - FSM is not encoded by XST when there is no initial condition

描述

I coded to infer two FSMs in the code, but XST encodes only one FSM.

What causes this problem?

解决方案

XST can infer an FSM only if there is a power-up state or reset condition; when this is not the case, XST cannot infer an FSM. Refer to the ISE Language Templates for examples of coding state machines with reset conditions.

AR# 22761
日期 12/15/2012
状态 Active
Type 综合文章
的页面