General Description: RLOCs of the form, R0C0.FFX, attached to single flip-flop macros may cause Map to issue the following error message if the primitive flip-flops underlying the macro do not already have RLOCs already attached to them:
<INPUT> "ERROR 0 - FMAP symbol - RLOC parameter suffix doesn't match block type" </INPUT>
XACT STEP 5.2.1 or and earlier versions allowed you to add these types of RLOC attributes to flip-flop macros such as the 4K family FDP, or the FDE flip-flop macros, even though the underlying FDCE's in these macros did not have RLOCs attached to them.
Schematic users using RLOCs need to be especially aware of this discrepancy between XACT 5.x and M1.
Reference: 12428
解决方案
Review your design and determine which of the components with RLOC attributes attached to them are macros. For those components that are macros, check to see whether the underlying flip-flop primitives (FDCE's or FDPE's) have RLOCs attached to them.
You can confirm whether a library component is a macro by referring to the online (Xilinx Manual Libraries Guide), which is accessible by typing the Dynatext "dtext" command.