UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 2366

4.1i XC4000 MAP - "ERROR: BLKNM parameter not supported on WAND symbol" (4000 family)

Description

Keywords: MAP, BLKNM, DECODE, WAND

Urgency: Standard

General Description:
The following error message is reported:

"ERROR: BLKNM parameter not supported on WAND symbol"

(This error message is misleading, because BLKNM properties actually ARE supported on regular Wired AND functions.)

解决方案

The real problem is that BLKNM properties are not valid on WANDs, which have a DECODE parameter attached to the WAND symbol. The DECODE parameter places the WAND components into Wide Edge Decoders during the implementation stage, and it is on these Wide Decoders that BLKNMs are not supported.

Use the LOC attribute if you wish to place the WAND into a wide edge decoder using the DECODE parameter.

Reference: 12798
AR# 2366
创建日期 06/09/1997
Last Updated 06/13/2002
状态 Archive
Type 综合文章