LogiCORE Ethernet AVB Endpoint v1.2 - Release Notes and Known Issues for ISE 11.1

Description

This Answer Record contains the Release Notes for the LogiCORE Ethernet AVB Endpoint v1.2, which was released in ISE 11.1 and includes the following: 

 

- General Information 

- New Features  

- Resolved Issues  

- Known Issues  

 

For installation instructions, general CORE Generator known issues, and design tools requirements, see the IP Release Notes Guide at: 

http://www.xilinx.com/support/documentation/ip_documentation/xtp025.pdf

解决方案

General Information 

 

The following are Generated out of CORE Generator: 

- Ethernet AVB Endpoint core netlist 

- Example design HDL top-level and associated HDL files 

- Demonstration test bench to exercise the example design 

- Documentation Directory containing Data Sheet, Getting Started Guide, and User Guide 

 

New Features 

 

- ISE 11.1 software support 

- Spartan-3, Spartan-3E, and Spartan-3A support 

 

Resolved Issues 

 

- For Spartan-3A DSP, the core contained an incorrect clock enable in the 8 KHz clock derivation logic. 

- version fixed: v1.2 

- CR 481302 

 

- MAC Header filter issues. 

- version fixed: v1.2 

- CR 480159 

- The Broadcast Address recognition logic had a pipeline delay bug: the 1st 5 bytes of the MAC DA were correctly identified. However, an error in the 6th byte incorrectly caused a Broadcast Address to be signaled. 

- A similar issue existed for the eight configurable MAC Header Filters. These are capable of recognizing the bit pattern of the first 16 bytes in a received frame. Like the Broadcast recognition bug, a bit error in the last byte of this check (the 16th byte in this case) could slip through unnoticed, resulting in a false filter match. 

 

- The core is not compliant with the P802.1AS specification for PTP frame identification. 

- version fixed: v1.2 

- CR 488623 

- PTP packets were incorrectly identified on the receiver data path using the Destination Address; they should be identified using the Length/Type field. 

 

- Out-of-date resource utilization figures were used in the Datasheet. 

- version fixed: v1.2 

 

Known Issues 

 

- none