AR# 32308

10.1.03 ISE - Error:Xilinx ISE has stopped working

描述


When I try to start up the ISE 32-bit and 64-bit version, I see an error. Windows says (in 5 seconds of booting) Xilinx ISE has stopped working.

------------------------

The Error Message

------------------------

64-bit

Problem signature:
Problem Event Name: APPCRASH
Application Name: _pn.exe
Application Version: 1.0.0.1
Application Timestamp: 48ab97a5
Fault Module Name: libScript_Interp.dll
Fault Module Version: 0.0.0.0
Fault Module Timestamp: 48897048
Exception Code: c0000005
Exception Offset: 0000000000001bf5
OS Version: 6.0.6001.2.1.0.256.4
Locale ID: 1033
Additional Information 1: 0b98
Additional Information 2: d32576b6a42caf169c692c459d588845
Additional Information 3: 2d74
Additional Information 4: 5ea240b120bac2748c4a5553519b592b

32-bit version

Problem signature:
Problem Event Name: APPCRASH
Application Name: _pn.exe
Application Version: 1.0.0.1
Application Timestamp: 48aba92c
Fault Module Name: libScript_Interp.dll
Fault Module Version: 0.0.0.0
Fault Module Timestamp: 48897e78
Exception Code: c0000005
Exception Offset: 000018db
OS Version: 6.0.6001.2.1.0.256.4
Locale ID: 1033
Additional Information 1: 49b4
Additional Information 2: 53b9db0ea92787b594c730768206c926
Additional Information 3: 179f
Additional Information 4: 81836016ec7e90d7d06228c13b494949

解决方案


To get the ISE work, follow the steps below:

- Launch the 32-bit version of Project Navigator.
- From menu bar, select Edit->Preferences.
- In the "Category" column, select the "HTML Browser" category.
- In the "HTML Browser" section, change the option from Embedded to External/System and click OK.