AR# 32482

11.1 PlanAhead - Does PlanAhead DRC report single-ended clocks on the N side of a differential pair?

Description

I accidentally constrained my single-ended clock to the N side of a Global Clock differential pair.  

 

Why did PlanAhead allow me constrain the clock to this location, and why did DRC not report it?

解决方案

PlanAhead currently Auto-Places clocks only to the P side, but allows you to assign the clock to the N side without a DRC error.  

 

This problem is scheduled to be fixed in a future software release.

AR# 32482
创建日期 04/10/2009
Last Updated 05/21/2014
状态 Archive
Type 综合文章