AR# 38036

7.1i CPLDfit : ERROR:Cpld:832 - 'q' is assigned to an invalid location ('BANK2') for this

描述


Trying to assign signals use the sytax of a bank number for a XC9500XV device instead of a pin number results in CPLDfit failures



ERROR:Cpld:832 - 'q' is assigned to an invalid location ('BANK2') for this
device. This will prevent the design from fitting on the current device. 'q'
must be reassigned before attempting a re-fit.
ERROR:Cpld:832 - 'c' is assigned to an invalid location ('BANK2') for this
device. This will prevent the design from fitting on the current device. 'c'
must be reassigned before attempting a re-fit.
ERROR:Cpld:832 - 'd' is assigned to an invalid location ('BANK2') for this
device. This will prevent the design from fitting on the current device. 'd'
must be reassigned before attempting a re-fit.
ERROR:Cpld:868 - Cannot fit the design into any of the specified devices with
the selected implementation options.
ERROR: Fit failed
Reason:

解决方案


This is not a supported syntax for the XC9500XV
NET "C" LOC = "BANK2" ;
NET "D" LOC = "BANK2" ;
NET "Q" LOC = "BANK2" ;

To workaround the issue the user should assign to a specific pin.


The XC9500XV part is discontinued and should not be used for new designs.