AR# 38982: 12.3 EDK, Chipscope_AXI_Monitor - ERROR:EDK:1526 - 64 bit-width connector assigned to 32 bit-width port
AR# 38982
|
12.3 EDK, Chipscope_AXI_Monitor - ERROR:EDK:1526 - 64 bit-width connector assigned to 32 bit-width port
描述
When using the ChipScope AXI Monitor for a AXI4-Stream interface, a connector mismatch error may occur:
make: *** [implementation/system.bmm] Terminated ERROR:EDK:1526 - INST:axi_dma_0 PORT:m_axis_mm2s_tdata CONNECTOR:DMA2WIDGET_MM2S_TDATA - /home/mikeru/xps_builds/axi_systems/axi_monitor/sp605/axi_monitor_test_cases/ M.81a/sp605_axi_dma_w1/edk/system.mhs line 314 - 64 bit-width connector assigned to 32 bit-width port
How do I resolve this issue?
解决方案
This issue may occur due to a bug in the EDK tools, or due to a mismatch of MPD BUS_INTERFACE. To work around the issue, manually parameterize the ChipScope AXI Monitor core to the correct interface widths when different from default widths.