AR# 40911

Spartan-6 What is the POR (Power on Reset) Threshold Voltage?

描述

The Spartan-6 FPGAData Sheet (DS162) does not specify a POR threshold voltage for the Spartan-6 devices, as previous Spartan families had. What are the equivalent specifications for power on reset threshold levels?

解决方案

Spartan-6 FPGA does not have the same POR Threshold Voltage as the Spartan-3 families do.

For Spartan-6 FPGA, when powering on the device the minimum operating condition levels found in the data sheet for VCCINT, VCCAUX and VCCO can be used as the minimum POR threshold.

If programming @ 1.8v then the minimum VCCO2 spec must be met which is 1.65V.

Once the Spartan-6 device is powered the voltage must NOT drop below the VDRINT and VDRAUX minimum levels as specific in the Spartan-6 Data Sheet.

For queries on the Spartan-3 POR threshold levels please see(Xilinx Answer 19816).