AR# 46857

13.4 EDK - "ERROR:Pack:2501 - Symbol " "of type MCB has a property "MEM_DDR3_WRT_RECOVERY" with an illegal value of "3"

描述

If I use axi_s6_ddrx_0, an error similar to the following occurs in Implementation:

ERROR:Pack:2501 - Symbol "u2/axi_s6_ddrx_0/axi_s6_ddrx_0/mcb_ui_top_0/mcb_raw_wrapper_inst/samc_0" of type MCB has a property "MEM_DDR3_WRT_RECOVERY" with an illegal value of "3".

解决方案

The equation of MEM_DDR3_WRT_RECOVERY is:

localparam  C_MEM_DDR3_WRT_RECOVERY = (C_MEM_TYPE !="DDR3") ? 5: ((C_MEM_TWR   +C_MEMCLK_PERIOD -1) /C_MEMCLK_PERIOD);

This message is generally based on clock frequency. 

The error can occur if an invalid clock frequency for DDR3 is used, (for example 200 MHz), which is below the ~300 MHz DDR3 minimum frequency.

AR# 46857
日期 09/16/2014
状态 Active
Type 综合文章
Tools More Less
IP