Virtex-6 FPGA ML605 Evaluation Kit - BRD and iMPACT show unexpected temperature values for ML605

Description

When running the ML605 Base Reference Design, unexpected temperatures can be encountered.


The fan will work as normal.  


What can cause this behavior?

解决方案

This behaviour can be caused by a problem with the power supply for the System Monitor on the ML605.

 

In this case, check the J19 and J35 jumper settings on your ML605 (both on pg. 34 of the ML605 schematic).

They should be set to the default setting, in accordance with User Guide (UG534), pg. 78.