This answer record discusses a known issue in 14.1 and later with the ChipScope ILA core in the ISE design tools.

解决方案

If you are using the ILA core in 14.1 or later with an 8-bit counter design, while in Single Trigger Run Mode, it is possible to see multiple trigger increments. 

The code example below increments "trig_count" by three on the rising edge of bit[7] instead of incrementing by one. 

This is a known issue that is scheduled to be fixed in a later version of the tools.

always @ (posedge clk)
begin
if(trigout)
trig_count <= trig_count + 8'b1;
end