If the version of ISE Design Suite used to program the Base TRD onto the KC705 board is different from that associated with the Base TRD files used, customers may experience a reduction in throughput (or no throughput at all) being seen in the Base TRD GUI.
The KC705 Base TRD can be re-loaded onto the Kintex-7 FPGA KC705 Evaluation Kit through iMPACT tool and the use of RDF0145, Restoring Flash Contents.
It is important when re-loading the KC705 Base TRD that customers use the correct version of ISE tools for the Base TRD version. For example, if a customer is using the KC705 Base TRD for 13.4, they should use iMPACT 13.4 tool to reprogram the flash device on the KC705. Failing to do so may result in a reduction in throughput, or no throughput at all, being reported in the Base TRD GUI.