AR# 50949

ZC702 - FMC LPC - Can the 34 differential user-defined pairs be used as single-ended user-defined signals?

描述

UG850, ZC702 Evaluation Board for the Zynq-7000 XC7Z020 All Programmable SoC User Guide, (v1.0), states that the LPC connections of the two FMC headers on the ZC702 implement a subset of 160-pin LPC connector connectivity.

Can the 34 differential user-defined pairs (34 LA pairs, LA00 - LA33) be used as single-ended user-defined signals?

解决方案

The 34 differential user-defined pairs (34 LA pairs, LA00 - LA33) connected between the J3 and J4 headers and the XC7Z020 EPP on the ZC702 can be used as single-ended user-defined signals.

UG850, ZC702 Evaluation Board for the Zynq-7000 XC7Z020 All Programmable SoC User Guide, (v1.1), includes this information.