AR# 51519

14.3 PlanAhead - A differential LVDS pair reports incorrectly P-side as input and N-side as output in PAD report

Description

In the 7 series architectures, it has been found that differential pairs may not be reported correctly in the PAD report from ISE or PlanAhead tools.

The P-side is reported correctly as an input but the N-side is incorrectly reported as an output.

解决方案

This has been found in PlanAhead tool when targeting a 7 series architectures. This issue only affectsthereporting process and the design is correct.

The issue has been fixed in PlanAhead tool 14.4.

AR# 51519
日期 12/12/2012
状态 Active
Type 已知问题
器件
  • Kintex-7
  • Artix-7
  • Virtex-7
Tools
  • PlanAhead - 14.1