(UG961), ZC706 Getting Started Guide, (v1.0), outlines on page 26 the steps to program the Quad-SPI Flash Memory with files from the SD card to run the Zynq-7000 PCIe TRD.
Figure 3-4, page 27, shows the SW11 Quad-SPI Flash Memory Settings; however, these are incorrect in UG961 v1.0.
What are the correct SW11 settings to boot from the SD card?
In order to program the Quad-SPI Flash Memory with files from the SD card on the ZC706, SW11 needs to be set to 00110, as shown below:
SW11 settings have been corrected in UG961, ZC706 Getting Started Guide, (v2.0).
Answer Number | 问答标题 | 问题版本 | 已解决问题的版本 |
---|---|---|---|
51899 | Zynq-7000 SoC ZC706 Evaluation Kit - Known Issues and Release Notes Master Answer Record | N/A | N/A |
AR# 54037 | |
---|---|
日期 | 05/17/2018 |
状态 | Active |
Type | 综合文章 |
Boards & Kits |