AR# 5510

M1.5 Trce, WARNING:bastw:169 - The pulse width for this signal is less than the minimum pulse-width

Description

Urgency : Standard

General Description:

The following warning/error occured when running trce on a

virtex design:

WARNING:bastw:169 - Pulse-width error at comp (mapped physical logic

cell) "ref_clk_77mhz" for signal "fpga_refclk". The pulse width for this

signal is less than the minimum pulse-width specification for the pin on

comp "ref_clk_77mhz" to which the signal is connected. The pulse

width for signal "fpga_refclk" was calculated from the following

constraint in the PCF file:

NET "fpga_refclk" PERIOD = 6.430 nS HIGH 3.220 nS ;

Datasheet v1.1 on the web p.25 states that the min. clock pulse

width for -5 device (Tch and Tcl) is 2.3 ns.

解决方案

The v1.1 datasheet on the web is outdated.

With the current speed file, Tch and Tcl for -5 is 3.312ns.

To get this information from the speed file, you can type the

following:

speedprint xcv300 -s 6

Look for Tch and Tcl value.

AR# 5510
创建日期 08/31/2007
Last Updated 01/18/2010
状态 Archive
Type 综合文章