AR# 56271

LogiCORE IP Video Timing Controller v6.0 - Why do I get an CRITICAL WARNING: [Common 17-161] Invalid option value '6.73400 6.73400' specified for 'delay' in Vivado 2013.1 or 2013.2, my clock source is from a clock mux?

描述

Why do I get a CRITICAL WARNING: [Common 17-161] Invalid option value '6.73400 6.73400' specified for 'delay' in Vivado 2013.1 or 2013.2 design tools, my clock source is from a clock mux?

CRITICAL WARNING: [Common 17-161] Invalid option value '6.73400 6.73400' specified for 'delay'. [zynq_base_trd/zynq_base_trd.srcs/sources_1/bd/design_1/ip/design_1_v_tc_1_0/design_1_v_tc_1_0_clocks.xdc:7

解决方案

This is because the delay must be determined from the PERIOD of a single clock, but a list of clocks connected to each BUFGMUX is returned.  The user should use the set_case_analysis to select the fastest clock of all BUFGMUXs to be used for timing analysis.  This can be done by using the following format.

    create_clock -period 10.0 [get_ports CLK_A]
    create_clock -period 15.0 [get_ports CLK_B]
    set_case_analysis 0 [get_ports SEL]