AR# 58056

2013.3 Vivado IP Integrator - TCL script generated in 2013.2 is not setting the MicroBlaze IP configurations correctly

描述

I have a TCL script generated in Vivado Design Suite 2013.2 that set the MicroBlaze configurations, however it is not settings these configurations correctly in the 2013.3 version.

For example, the TCL command below works in 2013.2 but is removing this parameter in 2013.3:

set_property -dict [list CONFIG.G_USE_CACHES {1}] [get_bd_cells /microblaze_1]

How can this be addressed?

解决方案

If the following MicroBlaze parameters are used in the Tcl script:

  • G_AREA_OPTIMIZED
  • G_DEBUG_ENABLED
  • G_MMU_ENABLED
  • G_USE_CACHES

These must be replaced in the TCL script with the following respective parameters:

  • C_USE_ICACHE and CONFIG.C_USE_DCACHE
  • C_AREA_OPTIMIZED
  • C_DEBUG_ENABLED
  • C_USE_MMU