UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 5939

4.1i Timing/Constraints - A FROM:THRU:TO:TIG constraints ignored.

Description

General Description:

A FROM:THRU:TO TIG constraint is used to ignore a specific path, but a number of blocked paths are less than expected and/or the instantiated paths.

For related information, please also see (Xilinx Answer 9297) and (Xilinx Answer 5965).

解决方案

Background:

GroupA = 300 elements/items

GroupB = 200 elements/items

If GroupA and GroupB cover the same elements/items, then GroupA is a superset of GroupB, and GroupB is a subset of GroupA. If we try to remove GroupA from GroupB, the tools are not able to remove these elements/items. If we try to remove GroupB from GroupA, the tools are able to remove these elements/items.

The Issue:

The FROM:THRU:TO TIG constraint is a superset of a smaller FFS time group. The issue is that the FFS time group and the TIG time group intersect; the TIG time group is not a subset of the FFS time group, so the tools cannot remove the correct items.

Unfortunately, the on-line documentation for the TIG constraint (Chapter 6 of the Development System Reference Guide at

http://toolbox.xilinx.com/docsan/4_1i/data/common/dev/chap06/dev06008.htm) does not explain the limitations or the general exceptions. For an exception to be applied to a timing specification by the timing software, the exception (TIG) must be a subset of another constraint. The TIG is actually a superset of FFS time group constraint; therefore, no TIG/exception can be applied.

Work-arounds:

A simple work-around is to do a global ignore (TIG) on the pins defined in the TIG time group, which will tell the tools to ignore these pins for all time groups.

Another way to work around the problem would be to create a timespec-specific ignore (TIG) of these pins. This will make a TIG group that is a subset of all the other time groups.

AR# 5939
创建日期 08/31/2007
Last Updated 01/18/2010
状态 Archive
Type 综合文章