Xact to M1.5i conversion documentation: preload_opt and mrinput attribute

描述

Keywords: Xact, M1.x, preload_opt, mrinput, conversion, attribute

Urgency: standard

General Description:

Application note http://www.xilinx.com/txpatches/pub/documentation/M1/convergd_m1_5.pdf
talks about the conversion of designs from Xact to M1.x. On page 20, there is a
chart to compare the attributes from Xact and how to convert it into M1.x.
There is a mention of the PRELOAD_OPT and the MRINPUT attributes which are not
available as attributes for M1.x but can be found in the gui.

解决方案

Solution:

The MRINPUT and PRELOAD_OPT are only 7000 series attributes. These attributes
are not supported on the 9500 family in M1.x.