My design works correctly in Vivado Design Suite 2014.2. 

After I upgrade it to Vivado 2014.3/2014.4, I receive numerous errors like the following in Simulink Simulation:

All Xilinx Blocks must be contained in a level of hierarchy with a System Generator Token.

Sometime there is only one internal error related to a constant. 

When I re-run it, it repeatedly generates the above error again.

The issue only occurs when the design reaches a certain level of complexity. 

A smaller design works fine.

What can cause this problem?

解决方案

This is a known issue related to how Sysgen works with DocBlock in 2014.3 and 2014.4. 


It will be fixed in a future release of Vivado Sysgen.

For Vivado 2014.3/2014.4, follow the instructions below to install attached patch:

  1. Unzip the patch file.
  2. Replace the xlGather_phase2.p located at : $VIVADO/scripts/sysgen/matlab
  3. Relaunch Sysgen, the issue should be fixed.
     

For other Vivado Sysgen Known issue, please refer to (Xilinx Answer 62168)

 