AR# 68269

HDCP 2.2 - Why do I get an error saying that module hdcp22_mmult_0_hdcp22_mmult could not be found?

描述

Why do I get an error saying that module hdcp22_mmult_0_hdcp22_mmult could not be found?

[Synth 8-439] module 'bd_0bf9_hdcp22_mmult_0_hdcp22_mmult' not found ["c:/very/very/very/deep/directory/structure/hdmi_rx_ss/bd/ip/ip/synth/bd_0bf9_hdcp22_mmult_0.v":124]

解决方案

The HDCP 2.2 IP and  the HDMI and DisplayPort Subsystems that use HDCP 2.2, are susceptible to the Windows path length restriction described in (Xilinx Answer 52787).

If you see this type of behavior on Windows, the current recommended work-around is to run the reset_project Tcl command to delete all Vivado-generated files.

This will put the project in a known good state, and you can then move the project to a temporary directory with a shorter path length such as C:/test.

链接问答记录

主要问答记录

相关答复记录

Answer Number 问答标题 问题版本 已解决问题的版本
52787 Vivado - "ERROR: [Common 17-143] Path length exceeds 260-Byte maximum allowed by Windows" N/A N/A
AR# 68269
日期 11/24/2016
状态 Active
Type 综合文章
IP