AR# 69970

2017.3 Zynq UltraScale+ MPSoC: XSDB using SmartLynq Data Cable does not show the MicroBlaze PMU MDM.

描述

On Zynq UltraScale+ devices, when using the Xilinx SmartLynq Data Cable, I do not see the MicroBlaze Performance Monitor unit (PMU) in the XSDB target list even after following the instructions in (Xilinx Answer 67871).

解决方案

The most likely cause of this issue is if your Xilinx SmartLynq Data Cable does not have the latest firmware.

To work around this issue, connect to the SmartLynq Data Cable from 2017.3 Vivado and run "update_hw_firmware reset".

See (UG1258) SmartLynq Data Cable User Guide for more details.

Follow the steps in (Xilinx Answer 67871) to access the MicroBlaze PMU MicroBlaze Debug Module (MDM).

AR# 69970
日期 05/03/2018
状态 Active
Type 综合文章
器件
Tools