AR# 9300

3.1i Virtex-E PAR - FATAL_ERROR:Place:xvkapselectio.c:340:1.12 - isOutput ...

Description

Keywords: PAR, xvkapselectio, xvkapselectio.c, 340, isOutput, place, placer

Urgency: Standard

General Description: A case has been seen where a design that
ran successfully in 2.1i SP6 fails in 3.1i with the error:

FATAL_ERROR:Place:xvkapselectio.c:340:1.12 - isOutput function
was called for a comp that is not an IO. Process will terminate. To
resolve this error, please consult the Answers Database and other
online resources at http://support.xilinx.com

解决方案

This problem can be worked around by setting the following
system environment variable:

setenv PL_NO_ASYNC_OUTPUT_CHECK 1 (workstations)
set PL_NO_ASYNC_OUTPUT_CHECK=1 (PCs)

This problem is scheduled to be fixed in the first major release
following version 3.1i.