FPGA Configuration 4000/Spartan - Can the readback-verify data pin be connected to the TDO pin?

Description

Can the readback data output be wired through the TDO pin?

解决方案

Yes. This has been successfully demonstrated on Spartan/4k devices, provided that JTAG is not used. Keep in mind that the TDO primitive must be instantiated; trying to LOC an OPAD to the TDO location will produce an error in MAP.