AR# 46004

AutoESL - Synthesis results in an error "@E [AP-70] test.cpp:21: error: wrong number of template arguments (0, should be 1)"

Description

The AutoESL tool reports the following errors during Synthesis:

@E [AP-70] test.cpp:21: error: wrong number of template arguments (0, should be 1)

解决方案

This error has been fixed in AutoESL version 2012.1.

For AutoESL 2011.4.2 and earlier, the workaround for this issue is to use the following coding style:


#include "ap_int.h"
//doesn't work
//typedef ap_uint<8> mydata;
//typedef mydata data_array[8];

//workaround:
typedef int mydata;
typedef mydata data_array[8];

//alternative workaround:
//typedef ap_uint<8> data_array[8];

void test (data_array input_array, data_array output_array)
{
for (int i=0; i<7; i++)
{
output_array[i] = input_array[i];
}
}