UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 54592

2013.1 CSE Server - Cannot run vcse_server with UNC path

Description

Currently, an attempt to run the vcse_server.exe executable from command prompt fails if the supplied path follows UNC and does not include a letter-mapped drive.

For example, the following command will fail:

\\xxx\xxx\nt64\Vivado\2013.1\bin\vcse_server

In this situation, an error similar to the following appears when attempting to open a cable connection:

"ERROR: [Labtools 27-147] cse_server: Could not open plug-in of the type: xilinx_platformusb. Please check to make sure the correct plug-in for this type is properly installed."

解决方案

Instead of the path format used above, use a path that includes a drive letter.

For example:
D:\xxx\xxx\nt64\Vivado\2013.1\bin\vcse_server

AR# 54592
创建日期 02/26/2013
Last Updated 03/29/2013
状态 Active
Type 已知问题
器件
  • Kintex-7
  • Artix-7
  • Virtex-7
Tools
  • ChipScope Pro
  • Vivado Design Suite - 2013.1