AR# 58406

Vivado Hardware Manager - ERROR:[Labtools 27-1974] Mismatch between the design programmed into the device XC7K325T_​0 and the probes file

描述

The following error appears when programming a device in Hardware Manager:

 

ERROR:[Labtools 27-1974] Mismatch between the design programmed into the device XC7K325T_0 and the probes file xxxx/impl_1/debug_nets.ltx.
The device design has 0 ILA core(s) and 0 VIO core(s). The probes file has 1 ILA coe(s) and 0 VIO core(s).
Resolution: Make sure the device probes file is up-to-date, then re-program the device.

 

What is the cause of this error?

解决方案

This following are possible fixes for this error:

 

  • Ensure that the .bit file and the .ltx file assigned to this device match each other.

  • Ensure that the capture clock to the ILA is a free running clock.

  • Ensure that timing requirement has been met after inserting Debug cores.

  • The error can be caused by a Signal Integrity issue on the board.
    A case was found where the issue was caused by a bad USB Cable.

  • In one case creating a new project resolved the error.

  • Ensure that the Version of the core matches the version of the tools, and hw_manager.

 

AR# 58406
日期 09/08/2017
状态 Active
Type 综合文章