On the ZC706, J37 FMC HPC header, FMC_HPC_LA17_CC_P / _N and FMC_HPC_LA18_CC_P / _N pins are routed to I/O pins, not SRCC nor MRCC pins on Bank 13.

Is this correct?

解决方案

FMC_HPC_LA17_CC_P / _N and FMC_HPC_LA18_CC_P / _N should be connected to Clock Capable pins.

This was missed during the PCB review, but should not affect board operation.

For all customer-designed PCBs that use the FMC interface, all CC nets should be connected to Clock Capable pins.